Skip Navigation LinksARCNVEVC ARC NVE VC

  • Resistant to concentrated chemicals i.e. Alkalis, Acids, and Solvents
    • Selection with confidence
    • Covers a broad range of chemical exposures
  • Specialized blend of reinforcements
    • Long term resistance to permeation
  • Thin film system or as a seal coat for ARC NVE TC
    • Versatile coating
    • Serves multiple applications
  • Deep penetrating primer system
    • Promotes exceptional adhesion
    • Concrete cohesively fails b​efore coating
 
Battery rooms
Sumps, trenches, and pits
Pickling rooms
Pickling/plating lines
Chemical containments
Loading stations
Bleaching areas
Pump equipment
Equipment bases
Click Here for Foreign Language Literature

 

 

Product Datasheet - ARC NVE Veil Coat Kit (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/adnvevc_EN.pdfProduct Datasheet - ARC NVE Veil Coat Kit (English)
SDS (Part B) - ARC CHP (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asCHP_EN.pdfSDS (Part B) - ARC CHP (English)
SDS (Part A) - ARC NVE LTGY Veil Coat (LTGY) (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asNVELTGYVA_EN.pdfSDS (Part A) - ARC NVE LTGY Veil Coat (LTGY) (English)
SDS (Part A) - ARC NVE Primer (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asNVEPA_EN.pdfSDS (Part A) - ARC NVE Primer (English)
SDS (Part A) - ARC NVE RD Veil Coat (Red) (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asNVERDVA_EN.pdfSDS (Part A) - ARC NVE RD Veil Coat (Red) (English)

Click Here for Foreign Language Literature

 

 

ARC Case Study 132: Pulp & Paper - High Temperature Bleached Pulp Stock Chesthttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN24250_ARC-CS132_HighTemp_Stock Chest_inter.pdfARC Case Study 132: Pulp & Paper - High Temperature Bleached Pulp Stock Chest
ARC Case Study 135: Pulp & Paper - Chlorine Dioxide Mixing Roomhttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN24253_ARC-CS135_NVE VC_UPM_Bleach room.pdfARC Case Study 135: Pulp & Paper - Chlorine Dioxide Mixing Room
ARC case Study 159: Secondary Containment and Adjacent Floor NVE VC Water (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/EN351047_ARC_CS159_Secondary Containment and Adjacent Floor_NVE_VC_Water.pdfARC case Study 159: Secondary Containment and Adjacent Floor NVE VC Water (English)
Case Study: ARC EG-1-NVE VC Chemical Uploading Bay Liner Wastewater (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/EN601448_ARC_CS_ARC_EG-1_NVE_Uploading_Bay_Chemical_Industry.pdfCase Study: ARC EG-1-NVE VC Chemical Uploading Bay Liner Wastewater (English)

Nominal Veil Kit coverage 19.3 m² (207 ft²) at 250 μm (10 mil) thickness

    The NVE VC two-layer system has 3 components:
     
  • NVE Primer​​ Coat (PC)
    1 x 2.1 L (.55 gal) container
    Nominal DFT of 125-180 μm (5-7 mil)
     
  • NVE Veil Coat (VC)
    1 x 4.8 L (1.27 gals) container
    Nominal WFT* of 250-375 μm (10-15 mil)
     
  • ARC CHP Catalyst
    ​1 X 250 ml container
     
    Note: Components are pre-measured and pre-weighed.
    Maintain transport temperature below 24°C (75°F.)
  • ​​

Available Colors​​

Red or Gray*
 
* Available from our EME Manufacturing
Facility only