Skip Navigation LinksARCS4 ARC S4+

  • Multi-functional Chemistry
    • Resists concentrated chemicals
  • High Cross-Link Density
    • Permeation resistant
    • Improved thermal stability
    • Enhanced mechanical proper​​ties
  • Spark testable per NACE SP 0188
    • Easy post application inspection
    • Facilitates quality assurance
  • High Adhesive Strength
    • No under-film corrosion
  • 100% solids; no VOCs; no free isocyanates
    • ​​Enhances safe use
 
​​Exhaust gas ductwork
Fans & housings
Chemical s​torage tanks
Chimneys & stacks
Heat exchangers
​​Tank linings


Composition MatrixA modified epoxy resin reacted with a modified cycloaliphatic amine curing agent
​​Composit​ion ​ReinforcementProprietary blend of surface modified mineral reinforcements
​​​​
​​​Cured Density​​​​​ 1.3 g/cc​ 81 lb/ cu.ft.
Flexural Strength(ASTM D 790)280 kg/cm2 (27.6 MPa)4,000 psi
Tensile Adhesion(ASTM D 4541) 330 kg/cm2 (32.4 MPa) 4,700 psi
Tensile Strength(ASTM D 638) 250 kg/cm2 (24.1 MPa) 3,500 psi
Tensile Elongation(ASTM D 638) 7%
Flexural Modulus(ASTM D 790) 1.8 x 104 kg/cm2 (1,765MPa) 2.5 x 105 psi
Shore D Durometer Hardness(ASTM D 2240)83
Vertical Sag Resistance at 21°C (70°F) and 250µm (10 mils)No sag
Maximum Temperature (Dependent on Service)​Wet Service
Dry Service
Post Cure Wet Service
60°C
150°C
95°C
140°F
300°F
203°F
​​
Click Here for Foreign Language Literature

 

 

Product Datasheet - ARC S4+ (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/ads4_EN.pdfProduct Datasheet - ARC S4+ (English)
Application Instructions - ARC S4+ (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/AI_S4_EN.pdfApplication Instructions - ARC S4+ (English)
SDS (Part A) - ARC S4+ (GY, RD) (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asS4za_EN.pdfSDS (Part A) - ARC S4+ (GY, RD) (English)
SDS (Part B) - ARC S4+ (GY and RD) (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asS4zb_EN.pdfSDS (Part B) - ARC S4+ (GY and RD) (English)

Click Here for Foreign Language Literature

 

 

ARC Case Study 102: Oil & Gas Industry - Transport Tankhttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.97_ARC-CS102_OIL-GAS-UPSTREAM_ACID-TANKER.pdfARC Case Study 102: Oil & Gas Industry - Transport Tank
ARC Case Study 119 - Fossil Power - Condensate Vesselshttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23606.14_ARC-CS119_POWER-FOSSIL-WATER-TREATMENT_CONDENSATE-POLISHER-VESSELS.pdfARC Case Study 119 - Fossil Power - Condensate Vessels
ARC Case Study 042: Mineral Processing - Butterfly Valvehttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.41_ARC-CS042_MINING-MINERAL-ORE-PROCESSING-REFINING_BUTTERFLY-VALVE.pdfARC Case Study 042: Mineral Processing - Butterfly Valve
ARC Case Study 061: Power Industry - Fossil - Sulfuric Acid Storage Tankshttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.60_ARC-CS061_POWER_FOSSIL_WATER-TREATMENT_SULFURIC-ACID-STORAGE-TANKS.pdfARC Case Study 061: Power Industry - Fossil - Sulfuric Acid Storage Tanks
ARC Case Study 066: Power Industry - Fossil - Containmenthttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.65_ARC-CS066_POWER-FOSSIL-WATER-TREATMENT_ACID-ALKALI-TANKER-UNLOADING-AREA.pdfARC Case Study 066: Power Industry - Fossil - Containment

Nominal, based on DFT 375 μm (15 mil)

Typically applied as 2-Coat System.

  • 1125 ml cartridge covers 3​.0 m2 (32.3 ft2)
  • 5 liter kit covers 13.3 m2 (143.1 ft2)
  • 16 liter kit covers 42.6 m2 (458.5 ft2)
 
Note: Components are pre-measured and pre-weighed.
Each kit includes mixing and application instructions.
5 liter kit includes tools.

Available Colors

Gray and Red