Skip Navigation LinksARCS7 ARC S7

  • Chemical resistant polymer matrix
    • Resists a broad spectrum of organic and inorganic acid
    • Resistant to cold wall delamination
  • Incorporates fine-graded sizes of reinforcements
    • Permeation resistant
  • Toughened resin structure
    • Resists cracking and disbondment under thermal cycling conditions
    • Survives rapid decompression
  • Low mixed viscosity
    • Easy to apply by conventional airless spray
  • High dielectric resistivity
    • Allows user to inspect with high voltage spark testing per NACE SP0188
  • Cured films have low surface energy
    • Reduces particle attachment
 
Flue gas ducts
Gas/Gas heat exchangers
Reactor domes
Process tanks
Electrostatic precipitators
Bag filters
Storage tanks
Chimney stack liners
​Evaporators​


Composition MatrixAn epoxy novolac vinyl ester resin reacted with a catalyst
​​Composit​ion ​ReinforcementA proprietary blend of high density reinforcements
​​​​
​​​Cured Density​​​​​1.6 gm/cc97 lb/ cu.ft.
Compressive Strength(ASTM D 695)1.124 kg/cm2 (110 MPa)16,000 psi
Flexural Strength(ASTM D 790)527 kg/cm2 (51.7 MPa) 7,500 psi
Flexural Modulus(ASTM D 790) 6.35 x 104 kg/cm2 (6.23 x 103 MPa) 9,003 x 105 psi
Tensile Elongation(ASTM D 638) 1.04%
Tensile Adhesion(ASTM D 4541)166 kg/cm2 (16.3 MPa)2,370 psi
Impact Resistance (direct)(ASTM D 2794) 9.1 N-m 80 in-lbs.
Durometer Hardness Shore D(ASTM D 2240)89
Maximum Temperature (Dependent on service)
For intermittent exposures at higher temperatures, consult factory​
Wet Service
Dry Service
135°C (Water)
180°C (Continuous)
275°F
355°F
VOC (Part A and B) EPA 24
@ 110°C (230°F)
0.07 kg/l 0.55 lb/gal
​​
Click Here for Foreign Language Literature

 

 

Product Datasheet - ARC S7 (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/ads7_EN.pdfProduct Datasheet - ARC S7 (English)
Application Instructions - ARC S7 (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/AI_S7_EN.pdfApplication Instructions - ARC S7 (English)
SDS (Part B) - ARC CHP (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asCHP_EN.pdfSDS (Part B) - ARC CHP (English)
SDS (Part A) - ARC S7 (WH, RD) (English)https://arcindustrialcoatings.chesterton.com/ArcDocuments/asS7A_EN.pdfSDS (Part A) - ARC S7 (WH, RD) (English)

Click Here for Foreign Language Literature

 

 

ARC Case Study 060: Power Industry - Foss - Flue Gas Chimney Lininghttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.59_ARC-CS060_POWER-NUCLEAR_FLUE-GAS-CHIMNEY-LINING.pdfARC Case Study 060: Power Industry - Foss - Flue Gas Chimney Lining
ARC Case Study 058: Nuclear Power-Alternative - Waste Incinerator Lininghttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.57_ARC-CS058_POWER-FOSSIL_FLUE-GAS-WASTE-ENERGY-PLANT.pdfARC Case Study 058: Nuclear Power-Alternative - Waste Incinerator Lining
ARC Case Study 059: Mining/Mineral & Ore Processing - Exhaust Stackhttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.58_ARC-CS059_MINING-MINERAL-ORE-PROCESSING_KILN-EXHAUST-STACK.pdfARC Case Study 059: Mining/Mineral & Ore Processing - Exhaust Stack
ARC Case Study 090: Fossil Power Industry - FGD Filters and Duckshttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.85_ARC-CS090_POWER-FOSSIL-FLUE-GAS_FGD-BAG-HOUSE-STRUCTURE.pdfARC Case Study 090: Fossil Power Industry - FGD Filters and Ducks
ARC Case Study 099: Chemical Processing - Glycolwater Storage Tankhttps://arcindustrialcoatings.chesterton.com/ArcDocuments/EN23593.94_ARC-CS099_CHEMICAL-PROCESSING-COOLING-SYSTEMS_GLYCOL-WATER-STORAGE-TANK.pdfARC Case Study 099: Chemical Processing - Glycolwater Storage Tank

500 μm (20 mil) WFT yields 400 μm (16 mil) DFT

  • 14 liter kit covers 28 m2 (300 ft2)
  • ARC S7 is recommended to be applied as a 2-coat system at 375 - 500 μm (12 - 15 mil) wft1) p​er coat. The recommended total dft2) is 650 -850 μm (25 - 30 mil)​​
     
    Note: Components are pre-measured​ and pre-weighed.
    Each kit includes mixing and application instructions.
     
  • 1.) wft = wet film thickness
    2). dft = dry film thickness​
    Maintain transport temperature below 24°C (75°F.)

Available Colors

Red and White